View: Security Screen – Devices
Tip
For more information about security, certificates, and encryption in CODESYS, see the following: Security in CODESYS
Function: The tab allows for the configuration and the transfer of controller certificates for encrypted communication with the controller. CSR files for certificate signing requests can be created for your own certificates.
View menu →Security Screen
Button:

Requirement: The CODESYS Security Agent add-on product is installed.
For more information, see the following:
The Devices tab shows all PLC devices configured in the project and their certificate store. If the communication path to the controller is configured, then you see the certificates that are stored in memory. Here you can create and configure new certificates on the controller. If a certificate currently in use is about to expire, then you get a warning when you log in to the device, and from there you can also switch directly to the Security Screen to renew the certificate.
Left side: Information | Devices and certificate store Shows the individual devices For example, there are the following categories for CODESYS Control Win SL:
|
Toolbar (left side) |
Ab CODESYS Control Version 3.5.18.0 also possible for the Own Certificates category: Import of a |
Right side: Information | If the active path to the controller is set and a device node is selected, then every use case for controller certificates is displayed on the right side.
As long as a certificate is not available for one of these use cases, it is displayed with the When a certificate store is selected on the left side, all certificates in it are displayed on the right side with the following information: Information: Use case; currently the controller component in question is displayed (example: CmpSecureChannel) Issued for: Name of the computer for which the certificate was issued (example: MyLocalPC) Issued by: Name of the computer on which the certificate was issued (example: MyLocalPC) Valid as of: Date (example: 07/20/2017 15:09:29) Valid until: Date (example: 07/20/2022 00:00:00. Depending on the remaining time of the certificate, the highlight color of the field changes: green -> yellow (two-thirds expired) -> orange (nine-tenths expired) -> red (expired). Note: When logging in to the controller, you get a warning when two-thirds or more of the validity period have expired. Then you can renew the certificate here in the Security Screen. Note: The remaining time and the colored highlighting in the Valid until column are calculated based on the time of the controller. If the time of the controller is unavailable, then the local time of the computer is used. A tooltip in the column also indicates which time source was used – for example Based on the time of the controller. Thumbprint: Hash value from specific properties of the certificate for purposes of identification (example: 279e1a46b86bd636c8e6f19fd51c222469ec49a8) Double-clicking a certificate entry opens the default Windows Certificate dialog. As a result, you can import a controller certificate into the Windows Certificate Store in the Controller Certificates folder, so that it is available for the encryption of boot applications, downloads, and online changes. If multiple certificates are available for one use case, then the system follows the steps below to determine the certificate that is used:
|
Drag&Drop: Moving of the certificate to another certificate store of the same device Double-clicking a certificate entry opens the default Windows dialog for displaying all certificate information. | |
Toolbar (right side) |
The Certificate Settings dialog opens for configuring the Validity period of the certificate and the Key length for the private key. Clicking OK saves the specified values in the CODESYS options. The values are reset at the next operation. As long as the certificate is being created, "(computing)" is displayed after the use case. You cannot cancel the create operation, but you can close the Security Screen and continue working.
If it is your own certificate, then the button opens a dialog which prompts you whether or not to keep the private key associated with the certificate. The answer Yes is set by default. Note that deleting the private key cannot be undone. If you delete your own certificate which is assigned to a use case, then a message will be displayed to indicate that this use case may no longer work after deletion. The use case will only work again after a new certificate has been created.
For CODESYS Control in Version 3.5.18.0 and higher, you can export
The predefined values in the dialog are adapted, if necessary, depending on the selected certificate.
The button opens the Certificate Signing Request Settings dialog. There you select the Component for which a CSR file is generated. In CODESYS V3.5 SP21 Patch 2 and higher, you can define the key length in the Key length (bit) field. If you are using an older version of CODESYS, then the field is hidden and the preset key length of 2048 bits is used. After you click OK to confirm, a message is displayed that the files are being created. You can see the status of the creation in the device log. To save the files to your computer, use the For more information, see the following: |